for Industry Yjv Na2xsy10 Kv 33kv 36kv 1*240mm2 3*240mm2 Copper Swa/Awa Armoured Mv Power Cable Copper XLPE Electrical Cable
Product Details
| Customization: | Available |
|---|---|
| Application: | Construction, Underground, Industrial, Power Station |
| Voltage: | High Voltage Cable |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Secured Trading Service
Diamond Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Fast Delivery
Quality Assurance
100% Finished Products Inspection
Product Certification
The supplier can deliver the goods within 15 days
The supplier provides quality assurance
The supplier inspects 100% of finished products.
The supplier's products already have relevant certification qualifications, including:
CCC
CE
UL
CQC
CQC
CQC
CQC
CQC
CCC
CE
UL
CQC
CQC
CQC
CQC
CQC
Sign In to see all verified strength labels (32)
Find Similar Products
Basic Info.
- Model NO.
- N2XSH N2XS(F)H N2XS(FL)H NA2XSH NA2XS(F)H NA2X
- Current
- AC Cable
- Insulation Material
- XLPE
- Sheath Material
- PVC
- Material Shape
- Round Wire
- Wire Core Material
- Red Copper Wire
- Certification
- ISO, CCC, CE, VDE
- Model
- N2xsh N2xs(F)H N2xs(FL)H Na2xsh Na2xs(F)H Na2xs(FL
- Brand
- Guowang
- Operating Temperature
- 90°c
- Certificates
- ISO,CCC,Ohsms
- Standard
- IEC/BS
- Color
- Customermized
- Armoured
- Sta,Swa,Awa,Ect
- OEM Service
- Yes
- Packing
- Drum
- Advantage
- Weather Resistance
- Transport Package
- Wooden Drum
- Specification
- 240mm2
- Trademark
- GUOWANG
- Origin
- China
- HS Code
- 8544601290
Packaging & Delivery
- Package Size
- 30.00cm * 30.00cm * 10.00cm
- Package Gross Weight
- 50.000kg
Product Description
33KV 1*240mm2 3*240mm2 SWA/AWA Armoured Power Cable for Industry
This product is suitable for fixed laying in the distribution network with AC 50Hz and rated voltage 26/35kV or industrial installations.
Occasion
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution. For example, it can be used in power distribution and other places within industrial and mining enterprises.
Product Characteristics
It has the characteristics of high normal operating temperature of conductor, simple structure, easy to use and not limited by laying drop.
This product uses steel wire armor, can withstand large mechanical tension.
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution. For example, it can be used in power distribution and other places within industrial and mining enterprises.
Product Characteristics
It has the characteristics of high normal operating temperature of conductor, simple structure, easy to use and not limited by laying drop.
This product uses steel wire armor, can withstand large mechanical tension.
Rated voltage
The rated voltage is 26/35kV, and the maximum voltage using the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable working temperature of the cable conductor for a long time is 90ºC. In the case of short circuit, the maximum temperature of the cable conductor shall not exceed 250 ° C and the duration shall not exceed 5s.
Ambient temperature
The minimum ambient temperature for cable operation is
-10 ° C.
Laying temperature
When installing and laying, the temperature should not be lower than 0ºC.
The rated voltage is 26/35kV, and the maximum voltage using the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable working temperature of the cable conductor for a long time is 90ºC. In the case of short circuit, the maximum temperature of the cable conductor shall not exceed 250 ° C and the duration shall not exceed 5s.
Ambient temperature
The minimum ambient temperature for cable operation is
-10 ° C.
Laying temperature
When installing and laying, the temperature should not be lower than 0ºC.
| Size | Conductor Structure (MM) |
Outer Diameter of Conductor (MM) |
Insulation Thickness (MM) |
Thickness of Outer Sheath (MM) |
Reference Outside Diameter (MM) |
Reference Weight (KG) |
| 3 x 50 | 10/2.58 | 8.4 | 10.5 | 3.8 | 89.5 | 11609.8 |
| 3 x 70 | 19/2.18 | 10.0 | 10.5 | 3.9 | 93.4 | 12767.1 |
| 3 x 95 | 19/2.58 | 11.6 | 10.5 | 4.1 | 97.2 | 14114.4 |
| 3 x 120 | 24/2.58 | 13.0 | 10.5 | 4.2 | 100.6 | 15448.2 |
| 3 x 150 | 30/2.58 | 14.6 | 10.5 | 4.3 | 104.5 | 16909.7 |
| 3 x 185 | 37/2.58 | 16.2 | 10.5 | 4.4 | 108.1 | 18463.6 |
| 3 x 240 | 48/2.58 | 18.5 | 10.5 | 4.6 | 113.7 | 20958.2 |
| 3 x 300 | 60/2.58 | 20.6 | 10.5 | 4.7 | 118.6 | 23497.6 |
| 3 x 400 | 61/2.94 | 23.8 | 10.5 | 5.0 | 126.3 | 27416.0 |
| 1 x 50 | 10/2.58 | 8.4 | 10.5 | 2.4 | 46.6 | 3855.9 |
| 1 x 70 | 19/2.18 | 10.0 | 10.5 | 2.5 | 48.2 | 4180.8 |
| 1 x 95 | 19/2.58 | 11.6 | 10.5 | 2.5 | 49.8 | 4584.3 |
| 1 x 120 | 24/2.58 | 13.0 | 10.5 | 2.6 | 51.4 | 4987.0 |
| 1 x 150 | 30/2.58 | 14.6 | 10.5 | 2.6 | 53.2 | 5444.1 |
| 1 x 185 | 37/2.58 | 16.2 | 10.5 | 2.7 | 55.0 | 5948.6 |
| 1 x 240 | 48/2.58 | 18.5 | 10.5 | 2.7 | 57.3 | 6685.0 |
| 1 x 300 | 60/2.58 | 20.6 | 10.5 | 2.8 | 59.8 | 7504.8 |
| 1 x 400 | 61/2.94 | 23.8 | 10.5 | 2.9 | 63.2 | 8664.9 |





Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Power Cable
- Medium Voltage Power Cable
- for Industry Yjv Na2xsy10 Kv 33kv 36kv 1*240mm2 3*240mm2 Copper Swa/Awa Armoured Mv Power Cable Copper XLPE Electrical Cable
Related Categories
Hot Searches
More