Rated Voltage: 3.6/35kv
Certification: ISO, CCC, CE, RoHS, VDE
Insulation: XLPE/PVC
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable pictures & photos
Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
US $0.01-100 / Meter
Min. Order: 100 Meters
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Henan, China
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CCC
to see all verified strength labels (20)
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
Yjv/Yjlv/Yjv22/Yjv32/Yjv62/Yjv72
Length
Lengths Customize
Conductor
Copper
Sample
Free
Transport Package
Standard Seaworthy Packing
Specification
1.5-300 mm2
Trademark
GUOWANG
Origin
China
HS Code
8544601290
Production Capacity
500km/Mouth

Packaging & Delivery

Package Size
200.00cm * 100.00cm * 200.00cm
Package Gross Weight
1500.000kg

Product Description

Product Description

 

System
This product is suitable for AC 50Hz, rated voltage 3.6/35KV distribution network or industrial installations in the fixed laying.
Occasion
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution.  For example, can be used in power distribution and other places within industrial and mining enterprises.
Features
It has the characteristics of high normal operation temperature of conductor, simple structure, convenient use, and not limited by laying drop.
Standards Compliant
Implementation Standards
GB/T 12706-2020 Extruded insulated power cables and accessories with rated voltages 1kV (Um=1.2kV) to 35kV (Um=40.5kV)
Additional Standards
Usage features
Rated voltage
The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/15kV, and the maximum voltage of the AC system should not exceed 17.5kV.
The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.
The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.
The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously the time does not exceed 5s.
Ambient Temperature
The minimum ambient temperature for cable operation is -10°C.
Laying Temperature
During installation and laying, the temperature should not be lower than 0ºC.
Bending Radius
When the single-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 20D. When the single-core cable is armored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is armored, the recommended minimum bending radius of the cable during installation is 12D. Note: D is the outer diameter of the cable.
Cores of Cable Wire
Color mark 1 core: omit  3 core: red, yellow, green (plus color tape)
Sheath
The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer's agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer's name, product model, rated voltage, and the manufacturer's name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete mark and the beginning of the next mark: should not exceed 500mm on the cable outer sheath; The cable insulation or tape should not exceed 200mm. Printed signs should be rub resistant and not easy to fall off, and the print on the surface should be legible.
Note: The mark on the surface of the sheath can also add other content according to the custom of the user or the manufacturer.
Product Parameters
Rated Voltage No. of CORES CORSS SECTIONAL(MM2) CONDUCTOR CORE DIAMETER (MM) CONDUCTOR SHIELD THICKNESS(MM) INSULATION THICKNESS(MM) NON METAL SHIELD SPEC. (MM) METAL SHIELD SPEC. (MM) BELT (MM) JACKET THICKNESS (MM) OVERALL DIAMETER (MM) WEIGHT (KG/KM)
3.6/6KV 3 3×25 7/2.18 6 0.8 2.5 0.7 30×0.10 60×0.20 2.1 35.6 1674.8
3 3×35 7/2.58 7 0.8 2.5 0.7 30×0.10 60×0.20 2.1 37.8 2030.8
3 3×50 10/2.58 8.4 0.8 2.5 0.7 30×0.10 60×0.20 2.2 41 2549.1
3 3×70 19/2.18 10 0.8 2.5 0.7 30×0.10 60×0.20 2.4 44.8 3260.6
3 3×95 19/2.58 11.6 0.8 2.5 0.7 40×0.10 60×0.20 2.5 48.5 4141
3 3×120 24/2.58 13 0.8 2.5 0.7 40×0.10 60×0.20 2.6 51.7 4968.7
3 3×150 30/2.58 14.6 0.8 2.5 0.7 40×0.10 60×0.20 2.7 55.3 5955.5
3 3×185 37/2.58 16.2 0.8 2.5 0.7 40×0.10 60×0.20 2.8 59 7081.9
3 3×240 48/2.58 18.5 0.8 2.6 0.7 40×0.10 60×0.20 3 64.8 8892.8
3 3×300 60/2.58 20.6 0.8 2.8 0.7 40×0.10 60×0.20 3.2 70.5 10875.2
3 3×400 61/2.94 23.8 0.8 3 0.7 40×0.10 60×0.20 3.4 78.7 13928.6
6/6KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 2.2 39.7 1913.5
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 2.3 42 2299.2
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 2.4 45.2 2837.2
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 2.5 48.9 3551.8
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 2.6 52.5 4451.6
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 2.7 55.8 5298.8
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 2.8 59.4 6306.2
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 2.9 63.1 7453.3
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 3.1 68.4 9253.6
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 3.3 73.3 11175.4
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 3.5 80.6 14160.5
6/10KV 3 3×25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 2.2 39.7 1913.5
3 3×35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 2.3 42 2299.2
3 3×50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 2.4 45.2 2837.2
3 3×70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 2.5 48.9 3551.8
3 3×95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 2.6 52.5 4451.6
3 3×120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 2.7 55.8 5298.8
3 3×150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 2.8 59.4 6306.2
3 3×185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 2.9 63.1 7453.3
3 3×240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 3.1 68.4 9253.6
3 3×300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 3.3 73.3 11175.4
3 3×400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 3.5 80.6 14160.5
Company Profile

 

Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power CableMv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power CableMv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power CableMv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power CableMv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
Certifications

 

Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
Packaging & Shipping

 

Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power CableMv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
FAQ

 

Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable pictures & photos
Mv Cable Yjv Yjlv Swa/Sta 1/3 Core 18/30kv Cu Conductor XLPE Insulated PVC/PE Sheathed Power Cable
US $0.01-100 / Meter
Min. Order: 100 Meters
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
172
Year of Establishment
2016-12-06