| Customization: | Available |
|---|---|
| Application: | Construction, Underground, Industrial, in Ceiling Air-Handling Plenums, Exposed or Concea |
| Voltage: | Low and Medium Voltage Cable |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC90 14/2 12/2 Mc/Bx/AC90/Acwu90/Teck90 Copper Conductor Al Aluminum
Interlocked Armored Cable
PPLICATION
AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance.
For use in ventilated, non-ventilated and ladder-type cable trays.
For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.
| AC90 600V - 2 Copper Conductors (Black/Red) | |||||||
| CONDUCTOR COUNT | CONDUCTOR SIZE | GROUND SIZE | INSULATION THICKNESS | CABLE DIAMETER | CABLE WEIGHT | MAX. PULLING TENSION | MIN. BEND RADIUS |
| 2 | 14 AWG | 14 AWG | 0.030 in | 0.430 in | 80 lbs/Mft | 66 lbs | 6.02 in |
| 0.76 mm | 10.9 mm | 120 kg/km | 30 kg | 153 mm | |||
| 2 | 12 AWG | 12 AWG | 0.030 in | 0.454 in | 99 lbs/Mft | 104 lbs | 6.36 in |
| 0.76 mm | 11.6 mm | 148 kg/km | 47 kg | 161 mm | |||
| 2 | 10 AWG | 12 AWG | 0.030 in | 0.512 in | 138 lbs/Mft | 166 lbs | 7.17 in |
| 0.76 mm | 13.0 mm | 206 kg/km | 75 kg | 182 mm | |||
| AC90 600V - 3 Copper Conductors | |||||||
| CONDUCTOR SIZE | GROUND SIZE | INSULATION THICKNESS | CABLE DIAMETER | CABLE WEIGHT | MAX PULLING TENSION | MIN. BEND RADIUS | AMPACITY (A) |
| 14/1 AWG | 14/1 AWG | 0.030 in. | 0.445 in. | 105 lbs/Mft | 99 lbs | 6.2 in. | 25 |
| 0.76 mm | 11.3 mm | 156 kg/km | 45 kg | 158 mm | |||
| 12/1 AWG | 14/1 AWG | 0.030 in. | 0.490 in. | 130 lbs/Mft | 157 lbs | 6.9 in. | 30 |
| 0.76 mm | 12.4 mm | 193 kg/km | 71 kg | 174 mm | |||
| 10/1 AWG | 12/1 AWG | 0.030 in. | 0.535 in. | 182 lbs/Mft | 249 lbs | 7.5 in. | 40 |
| 0.76 mm | 13.6 mm | 271 kg/km | 113 kg | 190 mm | |||
| 8/7 AWG | 10/7 AWG | 0.045 in. | 0.714 in. | 309 lbs/Mft | 418 lbs | 10.0 in. | 55 |
| 1.14 mm | 18.1 mm | 460 kg/km | 190 kg | 254 mm | |||
| 6/7 AWG | 8/7 AWG | 0.045 in. | 0.770 in. | 417 lbs/Mft | 702 lbs | 10.8 in. | 75 |
| 1.14 mm | 19.6 mm | 621 kg/km | 318 kg | 274 mm | |||
| 4/7 AWG | 8/7 AWG | 0.045 in. | 0.940 in. | 601 lbs/Mft | 1193 lbs | 13.2 in. | 95 |
| 1.14 mm | 23.9 mm | 894 kg/km | 541 kg | 334 mm | |||
| 3/7 AWG | 6/7 AWG | 0.045 in. | 0.990 in. | 721 lbs/Mft | 1622 lbs | 13.9 in. | 115 |
| 1.14 mm | 25.1 mm | 1073 kg/km | 736 kg | 352 mm | |||
| 2/7 AWG | 6/7 AWG | 0.045 in. | 1.040 in. | 891 lbs/Mft | 1922 lbs | 14.6 in. | 130 |
| 1.14 mm | 26.4 mm | 1326 kg/km | 872 kg | 370 mm | |||
| AC90 600V - 4 Copper Conductors | |||||||
| CONDUCTOR COUNT | CONDUCTOR SIZE | GROUND SIZE | INSULATION THICKNESS | ARMOUR O.D. | CABLE WEIGHT | MAX. PULLING TENSION | MIN. BEND RADIUS |
| 4 | 14 AWG | 14 AWG | 0.030 in. | 0.490 in. | 130 lbs/Mft | 131 lbs | 6.9 in. |
| 0.76 mm | 12.4 mm | 193 kg/km | 60 kg | 174 mm | |||
| 4 | 12 AWG | 14 AWG | 0.030 in. | 0.535 in. | 166 lbs/Mft | 209 lbs | 7.5 in. |
| 0.76 mm | 13.6 mm | 247 kg/km | 95 kg | 190 mm | |||
| 4 | 10 AWG | 12 AWG | 0.030 in. | 0.630 in. | 232 lbs/Mft | 332 lbs | 8.8 in. |
| 0.76 mm | 16.0 mm | 345 kg/km | 150 kg | 224 mm | |||