Underground Power Cable Medium Voltage Cu XLPE Insulated

Product Details
Customization: Available
Application: Construction, Industrial, Power Station, Telecommunication, Computer
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 0.01/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CCC
CE
to see all verified strength labels (32)
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
  • Underground Power Cable Medium Voltage Cu XLPE Insulated
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Exihibition
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
YJV
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
YJV
Brand
Guowang
Operating Temperature
Max 90°c
Ambient Temperature
Not Be Lower Than -10ºC
Laying Temperature
Not Be Lower Than 0ºC
Bending Radius
20d
Transport Package
Iron Tray Packing
Specification
As per the customer request
Trademark
GUOWANG
Origin
China
HS Code
8544492100
Production Capacity
500000/Week

Packaging & Delivery

Package Size
2100.00cm * 2100.00cm * 1050.00cm
Package Gross Weight
200.000kg

Product Description

Detailed Photos
Underground Power Cable Medium Voltage Cu XLPE Insulated
Underground Power Cable Medium Voltage Cu XLPE Insulated
Product Description

System
This product is suitable for AC 50Hz, rated voltage 3.6/35KV distribution network or industrial installations in the fixed laying.
Occasion
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution.  For example, can be used in power distribution and other places within industrial and mining enterprises.
Features
It has the characteristics of high normal operation temperature of conductor, simple structure, convenient use, and not limited by laying drop.
Implementation Standards
GB/T 12706-2020 Extruded insulated power cables and accessories with rated voltages 1kV (Um=1.2kV) to 35kV (Um=40.5kV)
Rated voltage
The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/15kV, and the maximum voltage of the AC system should not exceed 17.5kV.
The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.
The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.
The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously the time does not exceed 5s.
Ambient Temperature
The minimum ambient temperature for cable operation is -10°C.
Laying Temperature
During installation and laying, the temperature should not be lower than 0ºC.
Bending Radius
When the single-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 20D. When the single-core cable is armored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is unarmored, the recommended minimum bending radius of the cable during installation is 15D. When the three-core cable is armored, the recommended minimum bending radius of the cable during installation is 12D.
Note: D is the outer diameter of the cable.
Product Identification
Cores of Cable Wire
Color mark 1 core: omit  3 core: red, yellow, green (plus color tape)
Sheath
The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer's agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer's name, product model, rated voltage, and the manufacturer's name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete mark and the beginning of the next mark: should not exceed 500mm on the cable outer sheath; The cable insulation or
tape should not exceed 200mm.Printed signs should be rub resistant and not easy to fall off, and the print on the surface should be legible.
Note: The mark on the surface of the sheath can also add other content according to the custom of the user or the manufacturer.
Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils, if there is no agreement, the delivery length is not less than 100 meters.   Delivery of short sections of cable not less than 20 meters in length is permitted, the quantity of which does not exceed 10% of the total length of delivery, or any length of cable may be delivered according to mutual agreement.
Length Error
The measurement error of delivery length is ±0.5%.
 

Product Parameters
Rated Voltage No.OF CORES  CORSS SECTIONAL AREA(MM2) CONDUCTOR CORE DIAMETER(MM2) CONDUCTOR SCREEN THICKNESS(MM) INSULATION THICKNESS(MM) INSULATION SCREEN THICKNESS(MM) METAL SCREEN SIZE(MM) BETL(MM) JACKET THICKNESS(MM) OVERALL DIAMATER(MM) WEIGHT(KG/KM) DC RESISTANCE (OHM/KM)
3.6/6KV 1 25 7/2.18 6 0.8 2.5 0.7 30×0.12 30×0.20 1.8 18.6 544.4 0.727
1 35 7/2.58 7 0.8 2.5 0.7 30×0.12 30×0.20 1.8 19.6 656.8 0.524
1 50 10/2.58 8.4 0.8 2.5 0.7 30×0.12 35×0.20 1.8 21 813.9 0.387
1 70 19/2.18 10 0.8 2.5 0.7 30×0.12 35×0.20 1.8 22.6 1025 0.268
1 95 19/2.58 11.6 0.8 2.5 0.7 40×0.12 40×0.20 1.8 24.2 1295.7 0.193
1 120 24/2.58 13 0.8 2.5 0.7 40×0.12 40×0.20 1.8 25.6 1548.9 0.153
1 150 30/2.58 14.6 0.8 2.5 0.7 40×0.12 45×0.20 1.8 27.2 1850.6 0.124
1 185 37/2.58 16.2 0.8 2.5 0.7 40×0.12 50×0.20 1.8 28.8 2196 0.0991
1 240 48/2.58 18.5 0.8 2.6 0.7 40×0.12 55×0.20 1.9 31.5 2757.8 0.0754
1 300 60/2.58 20.6 0.8 2.8 0.7 40×0.12 60×0.20 2 34.2 3372.9 0.0601
1 400 61/2.94 23.8 0.8 3 0.7 40×0.12 60×0.20 2.1 38 4319 0.047
1 500 61/3.28 26.6 0.8 3.2 0.7 40×0.12 60×0.20 2.2 41.4 5367.5 0.0366
1 630 61/3.69 29.6 0.8 3.2 0.7 40×0.12 60×0.20 2.3 44.6 6607.7 0.0283
6/6KV 1 25 7/2.18 6 0.8 3.4 0.7 30×0.12 30×0.20 1.8 20.4 606.8 0.727
1 35 7/2.58 7 0.8 3.4 0.7 30×0.12 35×0.20 1.8 21.4 721.7 0.524
1 50 10/2.58 8.4 0.8 3.4 0.7 30×0.12 35×0.20 1.8 22.8 882.5 0 387
1 70 19/2.18 10 0.8 3.4 0.7 40×0.12 40×0.20 1.8 24.4 1097.8 0.268
1 95 19/2.58 11.6 0.8 3.4 0.7 40×0.12 45×0.20 1.8 26 1372.6 0.193
1 120 24/2.58 13 0.8 3.4 0.7 40×0.12 45×0.20 1.8 27.4 1629.4 0.153
1 150 30/2.58 14.6 0.8 3.4 0.7 40×0.12 50×0.20 1.8 29 1935.4 0.124
1 185 37/2.58 16.2 0.8 3.4 0.7 40×0.12 50×0.20 1.9 30.8 2298.9 0.0991
1 240 48/2.58 18.5 0.8 3.4 0.7 40×0.12 55×0.20 2 33.3 2858.3 0.0754
1 300 60/2.58 20.6 0.8 3.4 0.7 40×0.12 60×0.20 2 35.4 3441.4 0.0601
1 400 61/2.94 23.8 0.8 3.4 0.7 40×0.12 60×0.20 2.2 39 4386.7 0.047
1 500 61/3.28 26.6 0.8 3.4 0.7 40×0.12 60×0.20 2.2 41.8 5394.4 0.0366
1 630 61/3.69 29.6 0.8 3.4 0.7 40×0.12 60×0.20 2.4 45.2 6657 0.0283
6/10KV 1 25 7/2.18 6 0.8 3.4 0.7 30×0.12 30×0.20 1.8 20.4 606.8 0.727
1 35 7/2.58 7 0.8 3.4 0.7 30×0.12 35×0.20 1.8 21.4 721.7 0.524
1 50 10/2.58 8.4 0.8 3.4 0.7 30×0.12 35×0.20 1.8 22.8 882.5 0 387
1 70 19/2.18 10 0.8 3.4 0.7 40×0.12 40×0.20 1.8 24.4 1097.8 0.268
1 95 19/2.58 11.6 0.8 3.4 0.7 40×0.12 45×0.20 1.8 26 1372.6 0.193
1 120 24/2.58 13 0.8 3.4 0.7 40×0.12 45×0.20 1.8 27.4 1629.4 0.153
1 150 30/2.58 14.6 0.8 3.4 0.7 40×0.12 50×0.20 1.8 29 1935.4 0.124
1 185 37/2.58 16.2 0.8 3.4 0.7 40×0.12 50×0.20 1.9 30.8 2298.9 0.0991
1 240 48/2.58 18.5 0.8 3.4 0.7 40×0.12 55×0.20 2 33.3 2858.3 0.0754
1 300 60/2.58 20.6 0.8 3.4 0.7 40×0.12 60×0.20 2 35.4 3441.4 0.0601
1 400 61/2.94 23.8 0.8 3.4 0.7 40×0.12 60×0.20 2.2 39 4386.7 0.047
1 500 61/3.28 26.6 0.8 3.4 0.7 40×0.12 60×0.20 2.2 41.8 5394.4 0.0366
1 630 61/3.69 29.6 0.8 3.4 0.7 40×0.12 60×0.20 2.4 45.2 6657 0.0283
8.7/10KV 1 25 7/2.18 6 0.8 4.5 0.7 30×0.12 35×0.20 1.8 22.6 689.4 0.727
1 35 7/2.58 7 0.8 4.5 0.7 40×0.12 40×0.20 1.8 23.6 807.5 0.524
1 50 10/2.58 8.4 0.8 4.5 0.7 40×0.12 40×0.20 1.8 25 972.8 0 387
1 70 19/2.18 10 0.8 4.5 0.7 40×0.12 45×0.20 1.8 26.6 1193.1 0.268
1 95 19/2.58 11.6 0.8 4.5 0.7 40×0.12 50×0.20 1.8 28.2 1473 0.193
1 120 24/2.58 13 0.8 4.5 0.7 40×0.12 50×0.20 1.9 29.8 1747.8 0.153
1 150 30/2.58 14.6 0.8 4.5 0.7 40×0.12 55×0.20 1.9 31.4 2059.6 0.124
1 185 37/2.58 16.2 0.8 4.5 0.7 40×0.12 55×0.20 2 33.2 2430 0.0991
1 240 48/2.58 18.5 0.8 4.5 0.7 40×0.12 60×0.20 2.1 35.7 2998.8 0.0754
1 300 60/2.58 20.6 0.8 4.5 0.7 40×0.12 60×0.20 2.1 37.8 3589.6 0.0601
1 400 61/2.94 23.8 0.8 4.5 0.7 40×0.12 60×0.20 2.2 41.2 4529.9 0.047
1 500 61/3.28 26.6 0.8 4.5 0.7 40×0.12 60×0.20 2.3 44.2 5566.6 0.0366
1 630 61/3.69 29.6 0.8 4.5 0.7 40×0.12 60×0.20 2.4 47.4 6820.7 0.0283
8.7/15KV 1 25 7/2.18 6 0.8 4.5 0.7 30×0.12 35×0.20 1.8 22.6 689.4 0.727
1 35 7/2.58 7 0.8 4.5 0.7 40×0.12 40×0.20 1.8 23.6 807.5 0.524
1 50 10/2.58 8.4 0.8 4.5 0.7 40×0.12 40×0.20 1.8 25 972.8 0 387
1 70 19/2.18 10 0.8 4.5 0.7 40×0.12 45×0.20 1.8 26.6 1193.1 0.268
1 95 19/2.58 11.6 0.8 4.5 0.7 40×0.12 50×0.20 1.8 28.2 1473 0.193
1 120 24/2.58 13 0.8 4.5 0.7 40×0.12 50×0.20 1.9 29.8 1747.8 0.153
1 150 30/2.58 14.6 0.8 4.5 0.7 40×0.12 55×0.20 1.9 31.4 2059.6 0.124
1 185 37/2.58 16.2 0.8 4.5 0.7 40×0.12 55×0.20 2 33.2 2430 0.0991
1 240 48/2.58 18.5 0.8 4.5 0.7 40×0.12 60×0.20 2.1 35.7 2998.8 0.0754
1 300 60/2.58 20.6 0.8 4.5 0.7 40×0.12 60×0.20 2.1 37.8 3589.6 0.0601
1 400 61/2.94 23.8 0.8 4.5 0.7 40×0.12 60×0.20 2.2 41.2 4529.9 0.047
1 500 61/3.28 26.6 0.8 4.5 0.7 40×0.12 60×0.20 2.3 44.2 5566.6 0.0366
1 630 61/3.69 29.6 0.8 4.5 0.7 40×0.12 60×0.20 2.4 47.4 6820.7 0.0283
12/20KV 1 35 7/2.58 7 0.8 5.5 0.7 40×0.12 40×0.20 1.8 25.6 891.6 0.524
1 50 10/2.58 8.4 0.8 5.5 0.7 40×0.12 45×0.20 1.8 27 1060.9 0 387
1 70 19/2.18 10 0.8 5.5 0.7 40×0.12 50×0.20 1.8 28.6 1285.8 0.268
1 95 19/2.58 11.6 0.8 5.5 0.7 40×0.12 50×0.20 1.9 30.4 1584.2 0.193
1 120 24/2.58 13 0.8 5.5 0.7 40×0.12 55×0.20 1.9 31.8 1850.1 0.153
1 150 30/2.58 14.6 0.8 5.5 0.7 40×0.12 55×0.20 2 33.6 2181.8 0.124
1 185 37/2.58 16.2 0.8 5.5 0.7 40×0.12 60×0.20 2 35.2 2542.4 0.0991
1 240 48/2.58 18.5 0.8 5.5 0.7 40×0.12 60×0.20 2.1 37.7 3118.9 0.0754
1 300 60/2.58 20.6 0.8 5.5 0.7 40×0.12 60×0.20 2.2 40 3733.9 0.0601
1 400 61/2.94 23.8 0.8 5.5 0.7 40×0.12 60×0.20 2.3 43.4 4685.9 0.047
1 500 61/3.28 26.6 0.8 5.5 0.7 40×0.12 60×0.20 2.4 46.4 5732.9 0.0366
1 630 61/3.69 29.6 0.8 5.5 0.7 40×0.12 60×0.20 2.5 49.6 6998 0.0283
18/30KV 1 50 10/2.58 8.4 0.8 8 0.7 40×0.12 55×0.20 2 32.4 1335.7 0 387
1 70 19/2.18 10 0.8 8 0.7 40×0.12 60×0.20 2 34 1573.7 0.268
1 95 19/2.58 11.6 0.8 8 0.7 40×0.12 60×0.20 2.1 35.8 1887.5 0.193
1 120 24/2.58 13 0.8 8 0.7 40×0.12 60×0.20 2.1 37.2 2164.9 0.153
1 150 30/2.58 14.6 0.8 8 0.7 40×0.12 60×0.20 2.2 39 2512 0.124
1 185 37/2.58 16.2 0.8 8 0.7 40×0.12 60×0.20 2.2 40.6 2885.7 0.0991
1 240 48/2.58 18.5 0.8 8 0.7 40×0.12 60×0.20 2.3 43.1 3483.3 0.0754
1 300 60/2.58 20.6 0.8 8 0.7 40×0.12 60×0.20 2.4 45.4 4117.8 0.0601
1 400 61/2.94 23.8 0.8 8 0.7 40×0.12 60×0.20 2.5 48.8 5098.4 0.047
1 500 61/3.28 26.6 0.8 8 0.7 40×0.12 60×0.20 2.6 51.8 6170.6 0.0366
1 630 61/3.69 29.6 0.8 8 0.7 40×0.12 60×0.20 2.7 55 7462.6 0.0283
21/35KV 1 50 10/2.58 8.4 0.8 9.3 0.7 40×0.12 60×0.20 2.1 35.2 1496 0 387
1 70 19/2.18 10 0.8 9.3 0.7 40×0.12 60×0.20 2.1 36.8 1740.7 0.268
1 95 19/2.58 11.6 0.8 9.3 0.7 40×0.12 60×0.20 2.2 38.6 2062.6 0.193
1 120 24/2.58 13 0.8 9.3 0.7 40×0.12 60×0.20 2.2 40 2345.8 0.153
1 150 30/2.58 14.6 0.8 9.3 0.7 40×0.12 60×0.20 2.3 41.8 2701 0.124
1 185 37/2.58 16.2 0.8 9.3 0.7 40×0.12 60×0.20 2.3 43.4 3081.4 0.0991
1 240 48/2.58 18.5 0.8 9.3 0.7 40×0.12 60×0.20 2.4 45.9 3689.9 0.0754
1 300 60/2.58 20.6 0.8 9.3 0.7 40×0.12 60×0.20 2.5 48.2 4334.6 0.0601
1 400 61/2.94 23.8 0.8 9.3 0.7 40×0.12 60×0.20 2.6 51.6 5329.9 0.047
26/35KV 1 50 10/2.58 8.4 0.8 10.5 0.7 40×0.12 60×0.20 2.1 37.6 1639 0.387
1 70 19/2.18 10 0.8 10.5 0.7 40×0.12 60×0.20 2.2 39.4 1907.2 0.268
1 95 19/2.58 11.6 0.8 10.5 0.7 40×0.12 60×0.20 2.2 41 2217.7 0.193
1 120 24/2.58 13 0.8 10.5 0.7 40×0.12 60×0.20 2.3 42.6 2525.2 0.153
1 150 30/2.58 14.6 0.8 10.5 0.7 40×0.12 60×0.20 2.3 44.2 2867.6 0.124
1 185 37/2.58 16.2 0.8 10.5 0.7 40×0.12 60×0.20 2.4 46 3274.5 0.0991
1 240 48/2.58 18.5 0.8 10.5 0.7 40×0.12 60×0.20 2.5 48.5 3893.3 0.0754
1 300 60/2.58 20.6 0.8 10.5 0.7 40×0.12 60×0.20 2.5 50.6 4524.3 0.0601
1 400 61/2.94 23.8 0.8 10.5 0.7 40×0.12 60×0.20 2.6 54 5531.8 0.047
Company Profile

Underground Power Cable Medium Voltage Cu XLPE InsulatedUnderground Power Cable Medium Voltage Cu XLPE InsulatedUnderground Power Cable Medium Voltage Cu XLPE Insulated

Packaging & Shipping

Underground Power Cable Medium Voltage Cu XLPE Insulated

Exihibition

Underground Power Cable Medium Voltage Cu XLPE InsulatedUnderground Power Cable Medium Voltage Cu XLPE Insulated

Certifications

Underground Power Cable Medium Voltage Cu XLPE Insulated

FAQ

Underground Power Cable Medium Voltage Cu XLPE Insulated

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier