• N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
  • N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
  • N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
  • N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
  • N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
  • N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

Application: Construction, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: XLPE or PVC or PE
Material Shape: Round Wire
Samples:
US$ 0.01/Piece 1 Piece(Min.Order)
| Request Sample
freight forward
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Henan, China
Fast Delivery
The supplier can deliver the goods within 15 days
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Product Certification
The supplier's products already have relevant certification qualifications, including:
CCC
to see all verified strength labels (20)
  • Overview
  • Detailed Photos
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Exihibition
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
NA2XSY NA2XS2Y NA2XSH
Wire Core Material
Aluminum Conductor
Certification
ISO, CCC, CE, RoHS, VDE
Model
Al\XLPE\PVC\Sta Power Cable
Brand
Guowang
Operating Temperature
Max 90ºC
Ambient Temperature
Not Be Lower Than -15ºC
Laying Temperature
Not Be Lower Than 0ºC
Bending Radius
15D
Transport Package
Iron Tray Packing
Specification
As per the customer request
Trademark
GUOWANG
Origin
China
HS Code
8544601290
Production Capacity
5000000/Week

Product Description



 
Detailed Photos
N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable
Product Description

Scope of application
System
The product is suitable for fixed laying in the distribution networkor industrial installationswith AC 50Hz and rated voltage 3.6/6kV,6/6/6kV,6/10kV,8.7/10kV,8.7/15kV ,12/20kV,18/30kV,21/35kV 26/35kV.
Occasion
Fixed in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution. For example, it can be used in power distribution and other places within industrial and mining enterprises.
Product characteristics
It has the characteristics of high normal operating temperature of conductor, simple structure, easy to use, and is not limited by laying height.
This product incorporates double steel tape armor to withstand increased mechanical pressure.
Standards Compliant
Implementation Standards
GB/T 12706-2020 Rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cables and accessories.
Additional standard
Usage features
Rated voltage
The rated voltage is 3.6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/6kV, and the maximum voltage of the AC system should not exceed 7.2kV.
The rated voltage is 6/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/10kV, and the maximum voltage of the AC system should not exceed 12kV.
The rated voltage is 8.7/150kV, and the maximum voltage of the AC system should not exceed 17.5kV.
The rated voltage is 12/20kV, and the maximum voltage of the AC system should not exceed 24kV.
The rated voltage is 18/30kV, and the maximum voltage of the AC system should not exceed 36kV.
The rated voltage is 21/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
The rated voltage is 26/35kV, and the maximum voltage of the AC system should not exceed 40.5kV.
Operating temperature
The maximum allowable long-term working temperature of the cable conductor is 90°C; when short-circuited, the maximum temperature of the cable conductor does not exceed 250°C, continuously The time does not exceed 5s.
Ambient Temperature
Minimum working environment temperature -10ºC.
Laying Temperature
The laying temperature of cables should not be lower than 0ºC.
Bending Radius
The minimum bending radius of single-core cable without armour is recommended to be 20D. The minimum bending radius of single-core cable with armour is recommended to be 15D. The minimum bending radius of three-core cable without armour is recommended to be 15D. The minimum bending radius of three-core cable with armour is recommended to be 12D.
Note: D is the outer diameter of the cable.
Product Identification
Core
Color code
1 core: omitted
3 cores: red, yellow, green (add color ribbon)
Sheath
The outer sheath of the cable is usually black, but other colors can also be used in accordance with the manufacturer or buyer's agreement to adapt to its use environment. The cable should have a continuous identification of the manufacturer's name, product model, rated voltage, and the manufacturer's name identification can be a repeated identification of the manufacturer or trademark. The distance between the end of a complete logo and the beginning of the next logo should not exceed 500mm on the outer sheath of the cable; it should not exceed 200mm on the cable insulation or tape; the printed logo should be scratch-resistant and not fall off, and the printing on the surface Content should be clear and legible.
Note: The mark on the surface of the sheath can also add other content according to the custom of the user or the manufacturer.

Delivery and Tolerance
Delivery Length
Cables weighing less than 80kg are allowed to be delivered in coils. If there is no
agreement, the delivery length is allowed to be no less than 100 meters. Short sections of cables with a length of not less than 20 meters are allowed to be delivered, and their quantity does not exceed 10% of the total length of delivery, or cables of any length can be delivered according to mutual agreement.
Length Error
The measurement error of delivery length is ±0.5%.

Product Parameters
Rated Voltage No.OF CORES  CORSS SECTIONAL AREA(MM2) CONDUCTOR  CORE DIAMETER(MM) CONDUCTOR SCREEN THICKNESS(MM) INSULATION THICKNESS(MM) NON-METAL SCREEN SIZE(MM) METAL SCREEN SIZE(MM) BELT(MM) INNER JACKET THICKNESS(MM) ARMOUR SIZE(MM) OUTER JACKET THICKNESS(MM) OVERALL DIAMATER(MM) WEIGHT(KG/KM) DC RESISTANCE (OHM/KM)
3.6/6KV 3 25 7/2.18 6 0.8 2.5 0.7 30×0.10 60×0.20 1.2 35×0.5 2.2 40.2 2045.6 1.20
3 35 7/2.58 7 0.8 2.5 0.7 30×0.10 60×0.20 1.3 40×0.5 2.3 42.8 2310.7 0.868
3 50 10/2.58 8.4 0.8 2.5 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46 2647.60 0.641
3 70 19/2.18 10 0.8 2.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 3089.6 0.443
3 95 19/2.58 11.6 0.8 2.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 53.5 3573.4 0.32
3 120 24/2.58 13 0.8 2.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.1 4073 0.253
3 150 30/2.58 14.6 0.8 2.5 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 60.9 4629.2 0.206
3 185 37/2.58 16.2 0.8 2.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 64.6 5207.7 0.164
3 240 48/2.58 18.5 0.8 2.6 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.6 6190.9 0.125
3 300 60/2.58 20.6 0.8 2.8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.4 76.5 7257.2 0.100
3 400 61/2.94 23.8 0.8 3 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.5 9744.4 0.0778
6/6KV 3 25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 1.3 40×0.5 2.4 44.7 2418.4 1.20
3 35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46.8 2652.5 0.868
3 50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 1.4 45×0.5 2.6 50.4 3055.8 0.641
3 70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 1.5 50×0.5 2.7 54.3 3527.3 0.443
3 95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.9 4031.5 0.32
3 120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 61.4 4532.1 0.253
3 150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 3 65 5080.3 0.206
3 185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68.9 5713.4 0.164
3 240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.4 6677.6 0.125
3 300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.5 7666.4 0.100
3 400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 2 60×0.8 3.7 88.2 10003.4 0.0778
6/10KV 3 25 7/2.18 6 0.8 3.4 0.7 30×0.10 60×0.20 1.3 40×0.5 2.4 44.7 2418.4 1.20
3 35 7/2.58 7 0.8 3.4 0.7 30×0.10 60×0.20 1.3 45×0.5 2.4 46.8 2652.5 0.868
3 50 10/2.58 8.4 0.8 3.4 0.7 30×0.10 60×0.20 1.4 45×0.5 2.6 50.4 3055.8 0.641
3 70 19/2.18 10 0.8 3.4 0.7 40×0.10 60×0.20 1.5 50×0.5 2.7 54.3 3527.3 0.44
3 95 19/2.58 11.6 0.8 3.4 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.9 4031.5 0.32
3 120 24/2.58 13 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 61.4 4532.1 0.253
3 150 30/2.58 14.6 0.8 3.4 0.7 40×0.10 60×0.20 1.6 60×0.5 3 65 5080.3 0.206
3 185 37/2.58 16.2 0.8 3.4 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68.9 5713.4 0.164
3 240 48/2.58 18.5 0.8 3.4 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.4 6677.6 0.125
3 300 60/2.58 20.6 0.8 3.4 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.5 7666.4 0.100
3 400 61/2.94 23.8 0.8 3.4 0.7 40×0.10 60×0.20 2 60×0.8 3.7 88.2 10003.4 0.0778
8.7/10KV 3 25 7/2.18 6 0.8 4.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 2875.1 1.20
3 35 7/2.58 7 0.8 4.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 52.2 3151.5 0.868
3 50 10/2.58 8.4 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.7 55.6 3559.2 0.641
3 70 19/2.18 10 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 59.2 4026.5 0.44
3 95 19/2.58 11.6 0.8 4.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 63.3 4619.1 0.32
3 120 24/2.58 13 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 66.7 5143.3 0.253
3 150 30/2.58 14.6 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.3 5719.6 0.206
3 185 37/2.58 16.2 0.8 4.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.2 6383.3 0.164
3 240 48/2.58 18.5 0.8 4.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.7 7391.7 0.125
3 300 60/2.58 20.6 0.8 4.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.1 9238 0.100
3 400 61/2.94 23.8 0.8 4.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.6 10873.4 0.0778
8.7/15KV 3 25 7/2.18 6 0.8 4.5 0.7 30×0.10 60×0.20 1.4 45×0.5 2.5 49.8 2875.1 1.20
3 35 7/2.58 7 0.8 4.5 0.7 40×0.10 60×0.20 1.4 50×0.5 2.6 52.2 3151.5 0.868
3 50 10/2.58 8.4 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.7 55.6 3559.2 0.641
3 70 19/2.18 10 0.8 4.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 59.2 4026.5 0.44
3 95 19/2.58 11.6 0.8 4.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 63.3 4619.1 0.32
3 120 24/2.58 13 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 66.7 5143.3 0.253
3 150 30/2.58 14.6 0.8 4.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.2 70.3 5719.6 0.206
3 185 37/2.58 16.2 0.8 4.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 74.2 6383.3 0.164
3 240 48/2.58 18.5 0.8 4.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.7 7391.7 0.125
3 300 60/2.58 20.6 0.8 4.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 86.1 9238 0.100
3 400 61/2.94 23.8 0.8 4.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.6 10873.4 0.0778
12/20KV 3 35 7/2.58 7 0.8 5.5 0.7 40×0.10 60×0.20 1.5 55×0.5 2.8 57.1 3647.1 0.868
3 50 10/2.58 8.4 0.8 5.5 0.7 40×0.10 60×0.20 1.6 60×0.5 2.9 60.5 4080.2 0.641
3 70 19/2.18 10 0.8 5.5 0.7 40×0.10 60×0.20 1.6 60×0.5 3 64.1 4573.4 0.44
3 95 19/2.58 11.6 0.8 5.5 0.7 40×0.10 60×0.20 1.7 60×0.5 3.1 68 5165.6 0.32
3 120 24/2.58 13 0.8 5.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.2 71.4 5713.6 0.25
3 150 30/2.58 14.6 0.8 5.5 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 75.1 6318.3 0.21
3 185 37/2.58 16.2 0.8 5.5 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 79.1 7040.4 0.16
3 240 48/2.58 18.5 0.8 5.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 85.9 8904.1 0.125
3 300 60/2.58 20.6 0.8 5.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.8 90.8 9979.3 0.100
3 400 61/2.94 23.8 0.8 5.5 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 98.5 11710.5 0.0778
18/30KV 3 50 10/2.58 8.4 0.8 8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.3 72.5 5493.3 0.641
3 70 19/2.18 10 0.8 8 0.7 40×0.10 60×0.20 1.8 60×0.5 3.4 76.1 6049 0.443
3 95 19/2.58 11.6 0.8 8 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 80 6709.5 0.32
3 120 24/2.58 13 0.8 8 0.7 40×0.10 60×0.20 2 60×0.8 3.7 84.8 8155.4 0.253
3 150 30/2.58 14.6 0.8 8 0.7 40×0.10 60×0.20 2 60×0.8 3.8 88.4 8855.2 0.206
3 185 37/2.58 16.2 0.8 8 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 92.3 9653.5 0.164
3 240 48/2.58 18.5 0.8 8 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 97.8 10854 0.125
3 300 60/2.58 20.6 0.8 8 0.7 40×0.10 60×0.20 2.3 60×0.8 4.2 102.7 12015 0.100
3 400 61/2.94 23.8 0.8 8 0.7 40×0.10 60×0.20 2.4 60×0.8 4.5 110.4 13882.3 0.0778
21/35KV 3 50 10/2.58 8.4 0.8 9.3 0.7 40×0.10 60×0.20 1.9 60×0.5 3.5 78.7 6306.7 0.641
3 70 19/2.18 10 0.8 9.3 0.7 40×0.10 60×0.20 2 60×0.8 3.6 83.7 7724 0.443
3 95 19/2.58 11.6 0.8 9.3 0.7 40×0.10 60×0.20 2 60×0.8 3.8 87.6 8455.6 0.32
3 120 24/2.58 13 0.8 9.3 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 91 9130.5 0.253
3 150 30/2.58 14.6 0.8 9.3 0.7 40×0.10 60×0.20 2.2 60×0.8 4 94.8 9909.7 0.206
3 185 37/2.58 16.2 0.8 9.3 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 98.5 10696.2 0.164
3 240 48/2.58 18.5 0.8 9.3 0.7 40×0.10 60×0.20 2.3 60×0.8 4.3 104 11947.5 0.125
3 300 60/2.58 20.6 0.8 9.3 0.7 40×0.10 60×0.20 2.4 60×0.8 4.4 108.9 13153 0.1
3 400 61/2.94 23.8 0.8 9.3 0.7 40×0.10 60×0.20 2.5 60×0.8 4.7 116.6 15090.6 0.0778
26/35KV 3 3×50 10/2.58 8.4 0.8 10.5 0.7 40×0.10 60×0.20 2 60×0.8 3.7 85.6 7920.7 0.641
3 3×70 19/2.18 10 0.8 10.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.8 89.5 8624 0.443
3 3×95 19/2.58 11.6 0.8 10.5 0.7 40×0.10 60×0.20 2.1 60×0.8 3.9 93.1 9340.6 0.32
3 3×120 24/2.58 13 0.8 10.5 0.7 40×0.10 60×0.20 2.2 60×0.8 4.1 96.7 10087.3 0.253
3 3×150 30/2.58 14.6 0.8 10.5 0.7 40×0.10 60×0.20 2.3 60×0.8 4.2 100.6 10905 0.206
3 3×185 37/2.58 16.2 0.8 10.5 0.7 40×0.10 60×0.20 2.3 60×0.8 4.3 104.2 11716.1 0.164
3 3×240 48/2.58 18.5 0.8 10.5 0.7 40×0.10 60×0.20 2.4 60×0.8 4.5 109.8 13020.8 0.125
3 3×300 60/2.58 20.6 0.8 10.5 0.7 40×0.10 60×0.20 2.5 60×0.8 4.6 114.7 14267.7 0.1
3 3×400 61/2.94 23.8 0.8 10.5 0.7 40×0.10 60×0.20 2.6 60×0.8 4.9 122.4 16271.2 0.0778
Company Profile

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power CableN2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power CableN2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

Packaging & Shipping

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

Exihibition

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power CableN2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

Certifications

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

FAQ

N2xsy N2xs2y Na2xsh XLPE Insulation XLPE/PVC/PE Sheath Al Armoured Power Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
172
Year of Establishment
2016-12-06